AI auscultation flags weak heart pumping before the echo, outscoring cardiologists

Anam
Anam
Published Β·7 min read
Share 𝕏
AI auscultation flags weak heart pumping before the echo, outscoring cardiologists

A stethoscope recording heart sounds and ECG, read by a neural network, detected an ejection fraction of 40% or less with an AUROC of 0.904 in external validation.

A stethoscope that records heart sounds and a single-lead electrocardiogram, paired with a neural network, identified patients with a weakened left ventricle more accurately than a consensus of cardiologists in a reader substudy, according to a prospective multicentre study published in NEJM AI on 15 October 2026. In an external validation cohort of 964 patients, the model reached an area under the receiver operating characteristic curve (AUROC) of 0.904 for detecting a left ventricular ejection fraction (LVEF) of 40% or less.

The authors, led by Eiichiro Sato, describe the tool as a way to decide who most needs an echocardiogram, not as a replacement for one. That framing matters, because the study population was already on its way to imaging, and the number of false positives at the chosen threshold is substantial.

The problem: a common condition that is hard to hear

Left ventricular systolic dysfunction, in which the heart's main pumping chamber ejects a reduced fraction of its blood with each beat, is common in older adults and is linked to a poor prognosis even before symptoms appear. Treatments that improve survival in heart failure with reduced ejection fraction are well established, so finding the condition early has clear value.

The difficulty is detection. Echocardiography is the standard test, but it needs equipment and trained operators, and access is uneven, particularly in primary care and in lower-resource settings. Conventional auscultation is fast and cheap but insensitive: a weakened ventricle does not always produce a clearly audible abnormality, and interpretation varies widely between clinicians. Blood tests for natriuretic peptides help but are not specific to reduced ejection fraction.

That gap has driven a decade of work on algorithms that infer cardiac function from signals that are easy to collect. Most of the early evidence came from the 12-lead ECG, where deep learning models trained on paired ECG and echocardiogram data learned to flag low ejection fraction. Moving the same idea onto a stethoscope brings it to the point of the physical examination.

Illustration: a digital stethoscope records heart sounds and an ECG trace at the same time.
Illustration: a digital stethoscope records heart sounds and an ECG trace at the same time.

How the system works

In the study, adults referred for a clinically indicated echocardiogram underwent digital auscultation at four standard chest sites. At each site the device captured heart sounds together with a simultaneous single-lead ECG, so the model sees both the acoustic and the electrical activity of each cardiac cycle.

The classifier is an ensemble of two neural network types. A transformer, an architecture that weighs relationships across a whole sequence, is combined with a one-dimensional convolutional neural network, which picks up local patterns in a waveform. Ensembling different architectures is a common way to make predictions more stable than either model alone. The output is a probability of reduced ejection fraction, with echocardiography as the reference standard.

The study did not rely on accuracy figures alone. The team compared the model with logistic regression models built from clinical variables, from single-lead ECG features and from B-type natriuretic peptide (BNP), and with a reader substudy involving seven cardiologists.

The evidence

The model was trained on 2,359 patients (mean age 69.7 years, 40.4% female), of whom 8.9% had an LVEF of 40% or less. In that development cohort the four-site model reached an AUROC of 0.926 (95% CI, 0.911 to 0.939).

The more important test was external. The validation cohort of 964 patients came from a separate multicentre registry (mean age 68.6 years, 38.9% female), with reduced ejection fraction in 7.6%. There, the AUROC was 0.904 (95% CI, 0.876 to 0.930), a modest drop from development, which is expected when a model meets new data. At the chosen operating threshold, sensitivity was 86.3%, specificity 74.2% and overall accuracy 75.1%. The authors report that performance was consistent across prespecified subgroups.

In the 100-patient reader substudy, the model's accuracy was 82.0%, against 62.0% for the cardiologists' consensus (P=0.004). This comparison is narrower than it may sound. The abstract does not say whether the cardiologists had access to clinical history or other test results, and accuracy in a 100-patient sample is not directly comparable with the 75.1% seen in the larger validation cohort.

One practical finding concerns workflow. A simplified model using only two of the four recording sites kept an external AUROC of 0.903 (95% CI, 0.878 to 0.927), essentially the same as the full version. Fewer recording sites mean a shorter examination, which matters if the tool is to be used routinely.

Illustration: a heart with a weakened, dilated left ventricle, the condition the model is designed to flag.
Illustration: a heart with a weakened, dilated left ventricle, the condition the model is designed to flag.

What the numbers mean in practice

Sensitivity and specificity do not tell a clinician what a positive result means for the patient in front of them. That depends on how common the condition is. Using the validation cohort's prevalence of 7.6% and the reported sensitivity and specificity, roughly one in five positive results would correspond to a truly reduced ejection fraction, while a negative result would be correct about 98.5% of the time. These are our calculations from the published figures, not values reported by the authors, but they reproduce the paper's stated 75.1% accuracy.

That profile suits the role the authors propose: a pre-echocardiography "risk-enrichment" step. A negative result is reassuring, and a positive result raises the priority for imaging without being a diagnosis. In a general primary care population, where reduced ejection fraction is rarer than in patients already referred for echocardiography, the share of positive results that are true would be lower still.

How it fits with existing tools

The study is not the first attempt to put this kind of algorithm in a stethoscope. In the United States, the FDA cleared Eko Health's low ejection fraction tool, developed with Mayo Clinic, in 2024. It runs on the company's digital stethoscope during a routine examination. A pragmatic randomised trial in Nigeria, published in Nature Medicine in 2024, used a digital stethoscope with an AI algorithm adapted from a 12-lead ECG model to screen pregnant and postpartum women, and roughly doubled the detection of pregnancy-associated cardiomyopathy compared with usual care.

Against that background, the NEJM AI paper adds a prospective design, a separate external validation registry, a direct comparison with cardiologists and with BNP-based models, and evidence that two recording sites can be enough. It does not, on its own, show that using the tool changes outcomes.

The work was supported by Japan's KAKENHI research grant programme and by AMI Inc., a Japanese company that develops an AI-assisted stethoscope recording heart sounds and ECG together. Industry funding is common in device validation, but it is a reason to look for independent replication.

Limitations

  • A referred population. Everyone enrolled was already scheduled for echocardiography, so the prevalence of disease and the mix of patients differ from unselected screening. Performance in primary care or community screening has not been shown.
  • Accuracy, not outcomes. The study measures diagnostic accuracy. Whether AI auscultation leads to earlier treatment, fewer hospital admissions or lower costs needs randomised or pragmatic trials that measure those endpoints.
  • A single threshold. The target was an LVEF of 40% or less. Milder dysfunction, heart failure with preserved ejection fraction and valve disease are separate questions.
  • The comparator. Cardiologist auscultation is a reasonable benchmark for the stethoscope alone, but it is not how clinicians usually decide whom to send for imaging.
  • Generalisability. Details such as recording quality in noisy settings, performance across body habitus and use by non-specialist staff will determine whether the tool works outside research sites.

What to watch

The next questions are where the tool would be used and with what effect. Studies in primary care and community settings, with a lower and more realistic prevalence, will show how many positive results are true and how much imaging demand the tool generates. Randomised studies comparing AI-assisted auscultation with usual care, along the lines of the Nigerian trial, would show whether it changes diagnosis and treatment. Regulatory status outside Japan, and how the device performs when operated by nurses or general practitioners rather than research staff, will also shape its uptake.

For now, the study supports a specific, limited claim: in patients already referred for an echocardiogram, a stethoscope-based model separates those likely and unlikely to have reduced ejection fraction better than expert listening alone. It is evidence for triage, not for population screening.

This article is for information only and is not medical advice. Treatment decisions should be made with a qualified clinician.

Sources: NEJM AI via PubMed (Sato et al., 2026); Yesil Science; MedTech Dive; American Heart Association; NEDO